IQ should start from a verified installation. Before a turnover package moves from construction to qualification it needs a marked boundary, every IQ-blocking punch item closed, commissioning and balancing results, walked-down as-builts, calibration certificates and the equipment file. If one is missing, the package goes back.
In EU GMP Annex 1 (2022), 3,520 particles of 0.5 µm and larger per m³ is both the Grade A classification limit and the Table 5 monitoring maximum. In a 28.3 L sample that is about 100 counts, and one count reads as about 35 per m³, so site alert levels are clearer written as counts per sample.
Two accountable parties on one RACI row means nobody decides. The rows most likely to collect two As cross a handover: design changes after tender, vendor drawing approval, long-lead releases and readiness for IQ. Read every row as "X decides" and fix the ones that need two names before kickoff.
IEEE 519-2022 allows 8% total voltage distortion at 1 kV and below, but only 5% total and 3% per harmonic from 1 to 69 kV. A plant supplied at 22 kV has its point of common coupling on the MV side, so the stricter limits apply, and fan-wall harmonics pass straight through the transformer.
Operating theatres and isolation rooms rarely get a shutdown window, so maintenance fits between surgery lists. An isolation room may hold only 2.5 Pa negative, which one open ceiling panel next door can erase. Plan the dampers that hold the neighbours, the dirty-filter route and the tests before handback.
EU GMP Annex 15 allows some FAT results to be used at IQ and OQ when transport and installation do not affect them. For an AHU that means listing what the trip can change, from fan alignment to software version, retesting those on site and referencing the rest.
A loaded filter sheds part of its dust cake when the clamps release. Withdraw it through the upstream access section or sideways through a casing door, never through the section behind it. Then check every clamp by hand and log the new filter's differential pressure as the baseline.
EN 1822 ULPA classes add a nine each above H14: U15 99.9995%, U16 99.99995%, U17 99.999995% at MPPS. Semiconductor ISO Class 1 to 3 spaces need them. A pharma Grade A zone at ISO 5 rarely does, because people and seal leaks drive its counts; H14 with a sound seal usually carries it.
ISO 16890 rates what a filter captures; Eurovent energy classes, A+ to E, compare what it costs to run at reference conditions. Two ePM1 70% filters 50 Pa apart in average pressure drop differ by about 2,000 kWh a year at 10,000 m³/h. Ask for the class and the pressure drop at your airflow.
Annex 1 (2022) sets Grade A microbial limits as no growth and requires any growth to be investigated; FDA's 2004 aseptic guidance gives ISO 5 action levels of 1 CFU/m³ and 1 CFU per 4-hour settle plate. A plant filing in both markets can write one stricter rule and one investigation route.
A 1,000 m² fab bay with FFUs over 90% of its ceiling holds about 1,250 units of 1,200 × 600 mm. After handover each is a motor on the BMS, and the design documents should group the units by tool and zone so the fault logic can tell a work order from an alarm.
A plant room at 32 °C and 70% RH has a dew point near 26 °C. With 12 °C air inside, a TB3 casing frame sits at 21 to 24 °C and drips, while TB2 spans 24 to 27 °C and only its upper end clears. Ask for the tested kb and check it against the room's dew point.